Residual Current Circuit Breaker with over load protection
Residual Current Circuit Breaker with over load protection
Residual Current Circuit Breaker with over load protection
Residual Current Circuit Breaker with over load protection
  • Residual Current Circuit Breaker with over load protection
  • Residual Current Circuit Breaker with over load protection
  • Residual Current Circuit Breaker with over load protection
  • Residual Current Circuit Breaker with over load protection

Residual Current Circuit Breaker with over load protection

    Unit Price: USD 1 / Carton
    Payment Type: L/C,T/T,D/P
    Incoterm: FOB,CFR
    Min. Order: 100 Carton

Basic Info

Model No.KNBL1-32

CertificationIso9001-2000

Additional Info

Packagingcarton

TransportationOcean,Air

PortNingbo,SHANGHAI

Payment TypeL/C,T/T,D/P

IncotermFOB,CFR

Product Description


Sphere of application    
KNBL1-32 series leakage breaker ELCB  is suitable for the leakage protection of the line of A and S 50/60Hz, rated voltage single phase 240V,  rated current up to 32A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut off the power within 0.1s to protect human safety and prevent the accident due to the current leakage.
KNBL1-32 series Earth Leakage Circuit Breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and short-circuited as well as infre-quent changeover of the line in normal situation. Leakage Circuit Breaker It complies with standard of IEC/EN61009-1 and GB16917.1.
Basic specification and main parameters  ELCB

Earth Leakage Circuit Breaker
Leakage Circuit Breaker
ELCB

Technique parameter:

Frame class 32A
Rated working voltage 240/415V
Rated frequency 50/60Hz
Rated working current 10,16,20,25,32A
Rated residual operating current 0.03A
Rated residual un-operating current 0.015A
Sensibility AC Type,A Type 
Maximum operating time In t≤0.1s , 5In t≤0.04
Instant release type C type
Limiting value of un-operating current 6In
Rated limiting short-circuit current 3000A
Pole number 1P+N
Mechanical life 8000
Electric life 4000
Residual Current Circuit Breaker
Ac Residual Current Circuit Breaker

Product Categories : Residual Current Circuit Breaker With Over Load Protection > KNBL1-32 Residual Current Circuit Breaker With Over Load Protection