Residual Current Circuit Breaker RCBO KNLE1-63 CE 1P
Residual Current Circuit Breaker RCBO KNLE1-63 CE 1P
Residual Current Circuit Breaker RCBO KNLE1-63 CE 1P
  • Residual Current Circuit Breaker RCBO KNLE1-63 CE 1P
  • Residual Current Circuit Breaker RCBO KNLE1-63 CE 1P
  • Residual Current Circuit Breaker RCBO KNLE1-63 CE 1P

Residual Current Circuit Breaker RCBO KNLE1-63 CE 1P

    Unit Price: USD 1 / Bag/Bags
    Payment Type: L/C,T/T,D/P,Paypal
    Min. Order: 1 Bag/Bags

Basic Info

Model No.KNLE1-63

BrandKorlen

Breaking CapacityLow Voltage Circuit Breakers

OperationManual Type

SpeedNormal Type Circuit Breaker

Arc-extinguishing MediumAir

InstallationFixed

StructureElcb

Poles Number2

TypeCircuit Breaker

FunctionConventional Circuit Breaker

CertificationCe

Release TypeC

Rated Working Voltage240v

Frame32a

Rated Worling Current6;10;16;20;25;32a

Making And Breaking Capacity6000a

Additional Info

Packagingcarton

Productivity2000000pcs/month

TransportationOcean,Land,Air

Place of OriginWenzhou; Zhejiang; China

Supply Ability2000000pcs/month

CertificateCE,CB;VDE;

HS Code8536200000

PortNingbo,ShangHai

Payment TypeL/C,T/T,D/P,Paypal

Product Description

 KNLE1-63 series leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, three 
phase 240/415V and below, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed 
value, it will automatically cut off the power within 0.1s to protect human safety and prevent the accident due to the current leakage. KNLE1-32 series leakage breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and 
short-circuited as well as infrequent changeover of the line in normal situation. It complies with standard of IEC/EN61009-1 and GB16917.1.2. Sphere of applicati
 

  As for household appliances, refrigerators, washing machines etc which people often contact, using Residual Current Circuit Breaker to protect human safety and prevent the accident due to the current leakage. Earth Leakage Circuit Breaker

  ELCB is earth Leakage Circuit Breaker, mainly for AC,A and S 50/60Hz, rated voltage 230V(single phase)/400V(three phases), rated current up to 100A distribution network, used to prevent fire danger due to the damage of equipment insulation caused by the grounding fault current. It also can be used to protect the line from being overloaded and short-circuited as well as infrequent changeover of the line in normal situation.

Earth Leakage Circuit Breaker
Leakage Circuit Breaker
ELCB
Residual Current Circuit Breaker
Residual Current Circuit Breaker With Over Load Protection

Sequence
NO.
Test
Release
current /In
Start state Tripping
time
Expected
result
Not tripping
Tripping
1 C 1.13In Cold state t≤1h
2 C 1.45In Start right after
the serial NO.
1 test
t<1h
3 C 2.55In Cold state 1s Tripping
4 C 5In Cold state t≤0.1s Not tripping
5 C 10In Cold state t<0.1s Tripping

LE2

New Type Mini RCBO Swich











Product Categories : Residual Current Circuit Breaker With Over Load Protection > KNLE1-63 Residual Current Circuit Breaker With Over Load Protection