Product Categories
(Total 12 Products for Rccb Knl1 100 Tuv 4p)
Residual Current Circuit Breaker Rccb B-Type 40a-300ma
KNL5 series Residual current circuit breaker (without over-current protection) is suitable for the line of A,S and B 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Earth leakage circuit breaker 2P AC/A/S TYPE promotion
KNL5 series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Residual Current Circuit Breaker RCCB 50A 2P 4P
KNL5series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
RCCB with leakage protection function 63A frame
KNL5 series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Residual Current Circuit Breaker RCCB 16A-25A-32A-40A--63A
KNL5series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Residual Current Circuit Breaker ID DESIGN MAGNETIC TYPE
KNL5series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Residual Current Circuit Breaker 4P 63A 300MA 3KA
Application KNL1series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the...
Residual Current Circuit Breaker Electromagnetic IEC61008-1
KNL5-63 series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Residual Current Circuit Breaker KNL1-63 3KA CE 4P
KNL1 series Residual current circuit breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2pole)/
415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to...
Residual Current Circuit Breaker KNL1-63 3KA CB 4P
KNL1 series Residual current circuit breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2pole)/
415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to...
Residual Current Circuit Breaker KNL1-63 3KA SIRIM 4P
KNL1 series Residual current circuit breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2pole)/
415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to...
Residual Current Circuit Breaker KNL1-63 3KA SEMKO 2P
KNL1 series Residual current circuit breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2pole)/
415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to...
High Quality Products
Send Us a Message
We didn't put all products on website. If you can't find the product you're looking for, please contact us for more information.