10KA Leakage Residual Current Circuit Breaker House Hold
KNL6-63 series Residual current circuit breaker(without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Sale Residual current Circuit Breaker RCCB
The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk, thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. KNL1-63 Residual Current Circuit Breaker
Specifications
1.Provide protection against earth fault/leakage current and function of...
2P Low Voltage Earth Leakage Circuit Breaker RCCB
KNL9 series earth leakage circuit breaker adopt the new technology which is suitable in AC,A and S 50Hz/60Hz, 240/415V circuit with overload and earth leakage, it also can be employed to protect short circuit of circuit and motors as well as in frequent exchange of circuit and in frequent starting motors. They possess...
Residual Current Circuit Breaker Rccb B-Type 40a-300ma
KNL5 series Residual current circuit breaker (without over-current protection) is suitable for the line of A,S and B 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
RCCB with leakage protection function 63A frame
KNL5 series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Residual Current Circuit Breaker 6KA 4P A/AC/S TYPE
KNL5series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Residual Current Circuit Breaker s type 6ka 125A
DATA SHEET: KNL5series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the...
63A Leakage Magnetic House Hold RCCB
KNL5-63 series Residual current circuit breaker(without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...