Product Categories
(Total 12 Products for House Residual Current Cb)
House Circuit Breakers Without Over-Current Protection
KNL5-100 series without over-current protection of residual current circuit breaker is mainly used in power distribution lines used to indirect contact protection, can also be used to fire danger caused by ground fault current protection.this RCCB when electric shock protection failure also can be used as...
KNL1 RCCB Residual Current Circuit Breaker is in conformity with the standard of IEC61008.The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk,thus,it's suitable to avoid the shock hazard and fire caused by earth leakage.The RCCB is mainly suitable for use in...
The Residual current breaker (without over-current protection) is industrial area, commercial area, tall building and civil house. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will
cut off the power rapidly to protect human safety and prevent the accident...
63A 1p+N 3p+N Leakage Residual Current Circuit Breaker
KNL5-63 series Residual current circuit breaker(without over-current protection) RCCB is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the...
63A Leakage Magnetic House Hold RCCB
KNL5-63 series Residual current circuit breaker(without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Miniature circuit breaker for household distribution box 6KA
Miniature Circuit Breaker
Electronics Miniature Circuits Breaker
Automatic Miniature Circuit Breaker
Mini Circuit Breaker
MCB Standard IEC/EN 60898-1 IEC/EN 60947-2 Electrical features Rated current In A 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50,63 Poles 1P, 1P+N, 2P, 3P, 3P+N, 4P 1P, 2P, 3P, 4P Rated voltage Ue V...
10KA Leakage Residual Current Circuit Breaker House Hold
KNL6-63 series Residual current circuit breaker(without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
KNL1 RCCB Residual Current Circuit Breaker is in conformity with the standard of IEC61008.The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk,thus,it's suitable to avoid the shock hazard and fire caused by earth leakage.The RCCB is mainly suitable for use in...
KNL1 RCCB Residual Current Circuit Breaker is in conformity with the standard of IEC61008.The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk,thus,it's suitable to avoid the shock hazard and fire caused by earth leakage.The RCCB is mainly suitable for use in...
KNL1 RCCB Residual Current Circuit Breaker is in conformity with the standard of IEC61008.The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk,thus,it's suitable to avoid the shock hazard and fire caused by earth leakage.The RCCB is mainly suitable for use in...
Sale Residual current Circuit Breaker RCCB
The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk, thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. KNL1-63 Residual Current Circuit Breaker
Specifications
1.Provide protection against earth fault/leakage current and function of...
Residual Current Circuit Breaker Rccb B-Type 40a-300ma
KNL5 series Residual current circuit breaker (without over-current protection) is suitable for the line of A,S and B 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Categories
High Quality Products
Send Us a Message
We didn't put all products on website. If you can't find the product you're looking for, please contact us for more information.