KNM1L Moulded Case Circuit Breaker CB 100A
Sphere of application KNM1L series residual current circuit breaker are applies at the power distribution network of AC 50/60Hz, rated operation voltage of 400V(690V) and below, and rated current up to 800A. They can also be us to 800A. They can protect people against indirect contact and prevent tire disaster caused...
Residual Current Circuit Breaker 6KA 4P A/AC/S TYPE
KNL5series Residual current circuit breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power...
Residual Current Circuit Breaker KNL1-100 63A CB 4P
KNL1 series Residual current circuit breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2pole)/
415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to...
Residual Current Circuit Breaker RCBO KNLE1-100 CE 3P
KNLE1-63 series leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, three phase 240/415V and below, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut...
Residual Current Circuit Breaker ELCB KNLE1-100 CE 4P
KNLE1-63 series leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, three phase 240/415V and below, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut...
Residual Current Circuit Breaker RCBO KNLE1-100 CE 2P
KNLE1-63 series leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, three phase 240/415V and below, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut...
Moulded Case Circuit Breaker MCCB KNM1 CB 63A
Sphere of application KNM1 series moulded case circuit breaker(hereafter reffered to as simply breaker) The rated insulation voltage of the breaker is 800v (KNM1-63 is 500v),suitable for turn-on or turn off not frequency and starting a motor not frequently in the circuit of AC 50hz,rated working voltage 690V or bellow...
Moulded Case Circuit Breaker MCCB KNM1 CB 80A
Sphere of application KNM1 series moulded case circuit breaker(hereafter reffered to as simply breaker) The rated insulation voltage of the breaker is 800v (KNM1-63 is 500v),suitable for turn-on or turn off not frequency and starting a motor not frequently in the circuit of AC 50hz,rated working voltage 690V or bellow...
Moulded Case Circuit Breaker MCCB KNM1 CB 100A
Sphere of application KNM1 series moulded case circuit breaker(hereafter reffered to as simply breaker) The rated insulation voltage of the breaker is 800v (KNM1-63 is 500v),suitable for turn-on or turn off not frequency and starting a motor not frequently in the circuit of AC 50hz,rated working voltage 690V or bellow...
Moulded Case Circuit Breaker MCCB KNM1L CB 100A
Sphere of application KNM1L series residual current circuit breaker are applies at the power distribution network of AC 50/60Hz, rated operation voltage of 400V(690V) and below, and rated current up to 800A. They can also be us to 800A. They can protect people against indirect contact and prevent tire disaster caused...
Moulded Case Circuit Breaker MCCB KNM3 CB 100A
Sphere of application The rated insulation voltage of this circuit breaker is 750V which is applicable for the electricity distribution net of AC 50Hz, rated working voltage 690V and below, rated working current from 6A to 630A. It is used to distribute electric power and protect the line and power apparatus from...
Moulded Case Circuit Breaker MCCB KNM6 CB 100A
Sphere of application KNM5 series moulded case circuit breaker the rated insulation voltage of the circuit breaker is up to 1000V. It is suitable for AC 50Hz, rated working voltage to 690V, rated working current 10A to 800A in the distribution network circuit, used to distribute power and protect the line and power...